The device "TREND III" is used for non-invasive pressure-controlled breathing support.
The device is suitable for the treatment of obstructive sleep apnea in patients over 30 kg, especially when required by higher pressures and / or forms of respiratory failure.
Therapy pressure is administered via a breathing mask, which must be equipped with a passive exhalation valve to ensure exhalation air discharge.
Use of the device is intended for home medical care and professional health care facilities such as sleep laboratories and hospitals.
The "TREND III" is not suitable for use in motor vehicles, aircraft and helicopters.
General description of function
The blower sucks in the ambient air via a filter and transports it to the patient at a set pressure via a leakage tube circuit.
Therapy is non-invasive, provided via a breathing mask.
So that the expired air can escape, a vented CPAP mask must be used.
During therapy, oxygen can be supplied. Oxygen is either administered directly in the mask or in the tube circuit via an adapter.
An O2 safety valve must be used to ensure no oxygen flows into the device when therapy is not active.
Respiration therapy is carried out according to therapy parameters set using the control elements. In clinic mode, therapy can be monitored based on measurements via the display.
In the event of a misconduct of the set and permanently stored parameters in the device, visual and audible warning signals are output.
If the prescribed therapy is no longer possible due to a technical error, an acoustic signal is emitted for at least 2 minutes.
It is also possible to combine TREND III with the integrable humidifier AquaTREND III-NG.
Therapy data can be copied onto a USB stick and analysed using the PC software “easySET”.
The TREND III respiratory therapy device is available in the following types: CPAP, BILEVELS, BILEVEL ST, Auto CPAP, Auto BILEVEL S and Auto BILEVEL ST.
All TREND III devices have a respiratory trigger. The respiratory trigger recognises the patient’s difficulties in inhaling or exhaling and notifies the control equipment.
A volume-based trigger can be set for inhaling, while a flow-based trigger is available for exhaling (Values not adjustable for CPAP and AutoCPAP devices).
In combination with Optimal flank adjustment, the device ensures very comfortable therapy for patients, who feel like the device is gently supporting their natural breathing.
Therapy mode
Additional Information | |
Package Includes | (1)Hoffrichter Trend III (1) therapy tube (1) switching power supply (1) power supply cable (1) additional filter cassette (1) carrying case |